Spine Titanium Minimally Invasive Pedicle Screws

Short Description:


Product Detail

Product Tags

Product Features

Zenith-SE-System

The unique design of soft extension improves the intraoperative operability.

The soft tabs avoid the intraoperative mutual interference in the operation.
The intraoperatively visible and touchable facilitates multilevel rod-passing. The whole passing process doesn't need the auxiliary positioning with X-ray.

Soft Extension VS Hard Extension

1. During the multilevel or lower lumbar cases, the hard tabs intersect each other and may break.
2. The muscular counterforce gets the hard tabs closer, which interferes intraoperative observation.
3. The hard tabs require high precision of instruments for rod passing and X-ray assist. These delay the time and increase damage to surgeons.

Soft-Extension-VS-Hard-Extension
More-Reliable-Design

More Reliable Design

Unique locking from both lateral and medial integrates the soft tab and screw together firmly, avoiding the tab detaching during rod passing and pressing.

Soft tab and screw only connected laterally may detach during rod passing and pressing and delay operating time.

The screw cannot be close to anterior margin of the posterior column. The remained profile will make intraoperative tab breaking difficult and lead postoperative screw breaking.

Soft-tab-and-screw-only

ZATH’s

Others’

ZATH’s

The low profile better counters the anterior margin of the posterior column for reducing the risk of intraoperative screw breaking.

The thread design for cortical and cancellous bone can meet patients with various bone quality.

12.5 N.M intraoperative locking

Easy operation

12.5-N.M-intraoperative-locking

Breakable Setscrew

Arcuate-Rod-Geometry

Arcuate Rod Geometry

1. Decrease intraoperative rod bending and reduce breaking rate.
2. Unique design of rod holding for easy operation

Arcuate-Rod
Geometry
Dome-Laminoplasty-System-10

The low profile better counters the anterior margin of the posterior column for reducing the risk of intraoperative screw breaking.

The thread design for cortical and cancellous bone can meet patients with various bone quality.

Indications

Provide posterior, noncervical fixation as an adjunct to fusion for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis and/or lordosis); tumor; pseudarthritis; and/or failed previous fusion.

Clinical Application

Indications

Product Details

Zenith SE Mono-Angle Screw

fc748049

Φ5.5 x 35 mm
Φ5.5 x 40 mm
Φ6.0 x 40 mm
Φ6.0 x 45 mm
Φ6.5 x 40 mm
Φ6.5 x 45 mm
Φ6.5 x 50 mm
 

Zenith SE Multi-Angle Screw

774005f8

Φ5.5 x 35 mm
Φ5.5 x 40 mm
Φ6.0 x 40 mm
Φ6.0 x 45 mm
Φ6.5 x 35 mm
Φ6.5 x 40 mm
Φ6.5 x 45 mm
Φ6.5 x 50 mm
Zenith SE Breakable Set Screw

76b7b9d6

N/A
 

MIS Connection Rod (Straight)

7be3e0e6

Φ5.5 x 40 mm
Φ5.5 x 45 mm
Φ5.5 x 50 mm
Φ5.5 x 55 mm
Φ5.5 x 60 mm
Φ5.5 x 65 mm
Φ5.5 x 70 mm
Φ5.5 x 75 mm
Φ5.5 x 80 mm
Φ5.5 x 85 mm
Φ5.5 x 90 mm
Φ5.5 x 95 mm
Φ5.5 x 100 mm
Φ5.5 x 105 mm
Φ5.5 x 110 mm
Φ5.5 x 115 mm
Φ5.5 x 120 mm
Φ5.5 x 125 mm
Φ5.5 x 130 mm
Φ5.5 x 135 mm
Φ5.5 x 140 mm
Φ5.5 x 145 mm
Φ5.5 x 150 mm
Φ5.5 x 155 mm
Φ5.5 x 160 mm
Φ5.5 x 165 mm
Φ5.5 x 170 mm
Φ5.5 x 180 mm
Φ5.5 x 190 mm
Φ5.5 x 200 mm
 

MIS Connection Rod (Pre-Bent)

9458d4071

Φ5.5 x 40 mm
Φ5.5 x 45 mm
Φ5.5 x 50 mm
Φ5.5 x 55 mm
Φ5.5 x 60 mm
Φ5.5 x 65 mm
Φ5.5 x 70 mm
Φ5.5 x 75 mm
Φ5.5 x 80 mm
Φ5.5 x 85 mm
Φ5.5 x 90 mm
Φ5.5 x 95 mm
Φ5.5 x 100 mm
Φ5.5 x 105 mm
Φ5.5 x 110 mm
Φ5.5 x 115 mm
Φ5.5 x 120 mm
Φ5.5 x 125 mm
Φ5.5 x 130 mm
Φ5.5 x 135 mm
Φ5.5 x 140 mm
Material Titanium Alloy
Surface Treatment Micro-arc Oxidation
Qualification CE/ISO13485/NMPA
Package Sterile Packaging 1pcs/package
MOQ 1 Pcs
Supply Ability 1000+Pieces per Month